Standard Panel Series
The core of PolyVision architectural wall panels, Standard steel wall panels are extremely flat, resilient, and built to endure high-traffic environments. a3 CeramicSteel wall panels are bonded to a substrate and a backside sheet with an unfinished edge to create a paneled look when used with a sealed framing system. Master panels can be cut to size. Enhance the Standard Panel metal cladding by choosing from 2 finishes, 113 standard colors, custom colors or Surface Imaging.

Standard Panel 1-9
a3 CeramicSteel metal cladding panel made with cement bonded particle board, galvanized steel backer and an unfinished edge. 9 mm total thickness.

Standard Panel 1-13
a3 CeramicSteel metal cladding panel made with cement bonded particle board, galvanized steel backer and an unfinished edge. 13 mm total thickness.

Standard Panel 2-12
a3 CeramicSteel metal cladding panel made with calcium silicate fiberboard, galvanized steel backer and an unfinished edge. 12 mm total thickness.

Standard Panel 3-10
a3 CeramicSteel metal cladding panel made with medium density fiberboard, galvanized steel backer and an unfinished edge. 10 mm total thickness.

Standard Panel 3-13
a3 CeramicSteel metal cladding panel made with medium density fiberboard, galvanized steel backer and an unfinished edge. 13 mm total thickness.
Technical Information
Property |
Thickness |
Master Panel Size |
Best Fire Class Rating Possible* |
Panel Weight |
---|---|---|---|---|
Standard Panel 1-9 | 9.4 mm | 3050 mm x 1200 mm | N/A | 23.3 kg/m2 |
Standard Panel 1-13 | 13.4 mm | 3050 mm x 1200 mm | B | 23.3 kg/m2 |
Standard Panel 2-12 | 12.4 mm | 3050 mm x 1200 mm | A2 | 21.0 kg/m2 |
Standard Panel 3-10 | 10.4 mm | 3050 mm x 1200 mm | N/A | 15.0 kg/m2 |
Standard Panel 3-13 | 13.4 mm | 3050 mm x 1200 mm | N/A | 26.0 kg/m2 |
*According to the European Standard EN 13501-1
Seamless Framing System Recommendation
Excellent corrosion resistance when used with a sealed framing system that clamps, covers and seals the panel perimeter. Framing systems are not provided. Your PolyVision representative can direct you to our Architectural Partners who offer complete systems and framing solutions for installation.

Drawing for reference only—system not included.